MWM TEM the total Electronic management from MWM is ....


Case Study
Natural Gas based cogeneration Captive Power ....


Need more information / quotation

Read More...

SELECTION CHART FOR PRODUCER / WOOD GAS BASED GENSETS

MWM ENGINE TYPE
TCG 2032 V12
TCG 2032 V16
Mechanical Power (KWm)
2025
2700
Electrical output (KVA)
1974
2633
Rated Speed (RPM)
1000
1000
No. of Cylinders
12
16
Configuration V 60
Bore (mm)
260
260
Stroke (mm)
320
320
Combustion Type Lean Burn Spark Ignited
Intake system Turbo Charged
"Dimension (mm) - L
7800
8900
Dimension (mm) - W
2700
2750
Dimension (mm) - H
3700
3800
Genset Weight dry (Kg)>
40300
46800
 

Note:  
1)
Engine power rating according to ISO 3046
2)
The power output is rated for prime power duty
3)
The engine ratings are at standard operation & environment conditions.
4)
The electrical output is at 413V, 50 Hz and Power Factor = 1
5)
The values given in the data sheet are for information purposes only and are not binding.